Hospi-Gard®
IsoClean® CM
SPECIFICATIONS
| Motor/Blower
Assembly |
| Direct
drive, continuous duty 480 Watt motor with sealed-for-life bearings
and inherent overload protection located on the "clean side"
of the filter. Motor/blower assembly is mounted utilizing vibration
dampening rubber and is designed to provide rated airflow through
a 50% increase in initial static pressure. |
| Electrical |
| Standard
115 V, single phase, 60 Hz with 7/8-in. (21.4 mm) conduit knock-out.
Standard 220 V, 50 Hz (22.2 mm) conduit knock-out. Optional remote
mounted “ON/OFF” switch with speed control allows the
unit to be turned on from either inside or outside the room. Optional
hospital grade power cord available. |
| Construction |
| Welded
aluminum filter plenum and blower housing, sealed airtight. |
| Warranty |
| Limited
one year. |
| Hospital
Applications |
- Negative
Pressure Rooms
-
Emergency Rooms
-
Waiting Rooms
-
Sputum Induction
- Aerosol
Pentamidine Treatment
-
Intensive Care Units
-
Bronchoscopy Rooms
-
Renal Dialysis Rooms
|
| Other
Applications |
- Clinics
-
Nursing Centers
-
Physician Offices
- Homeless
Shelters
-
Addiction Recovery Centers
-
Correctional Facilities
|
| Options |
- Unit
with Remote Speed Control, Part No. 10970-002
- Unit
with Lockable Remote Speed Control, Part No. 10970-003
-
Unit with ULPA Filter Upgrade, Part No. 10970-004
-
Hospital grade Power Cord, Part No. 10660
-
12 in. (294 mm) Exhaust Collar, Part No. 24335-001
-
Anti-microbial Prefilter, Part No. 38101-002
-
1/4 -20 Eyebolts (set of 4), Part No. 62529-001
-
Room Pressure Monitor, Part No. 63337
-
Annunciator, Part No. 63338
|
 |
| Part
Number |
10970-001 |
| Airflow,
CFM (m3/hour) |
Variable
to 700 (1,190) |
| Maximum
BTU/Hour |
1508 |
Power
Requirements
Amps @ 115 V, 50/60 Hz
(230 V/50 Hz) |
4.2
(2.0) |
| UL
Listed |
All
Parts |
Dimensions,
Inches
(millimeters) |
A |
47.81
(1171) |
| B |
23.81
(583) |
| C |
17.50*
(428.7) |
Unit
Weight, lbs.
(kilograms) |
78
(35.38) |
| *Note:
Electrical Box adds two inches to overall height |
For
additional information,
please contact your local Representative or
Distributor.